21016A H-150/1.5 150 Nm3/hr Hydrogen Generator
Tag No.:21016A
Model:H-150/1.5
Name:Hydrogen Generator
1. Technical parameters of water electrolysis hydrogen generator
SN |
Name |
Value |
1.1 |
Model |
GHM-150/1.5 |
1.2 |
Rated hydrogen output |
150Nm3/h (30% -105% continuous, stable and adjustable) |
1.3 |
Rated oxygen output |
75Nm3/h |
1.4 |
Output hydrogen purity |
≥99.7%±0.2% (Out of electrolyzer) |
1.5 |
Purified hydrogen purity |
99.999% |
1.6 |
Purified hydrogen dew point |
-60℃ |
1.7 |
Output oxygen purity |
≥98.5+/-0.5% |
1.8 |
System work pressure |
1. 5Mpa |
1.9 |
Rated DC power consumption |
≤4.6KWh/Nm3H2+/-0.2 |
1.10 |
Control mode |
PLC+ upper computer |